RPC_S_CALL_FAILED - 1726 (0x6BE)

The remote procedure call failed.

Updated: Feb 21, 2026

Technical Meaning

The error code RPC_S_CALL_FAILED indicates that a remote procedure call (RPC) failed. This is a generic error message and does not provide specific details about the reason for failure.

Error Details

This error typically occurs when an RPC function returns with this status, signifying that the operation could not be completed successfully. The exact cause of the failure can vary depending on the context in which the RPC call was made.

Usage Context

RPC_S_CALL_FAILED is commonly encountered in scenarios where a client application attempts to invoke a remote procedure hosted by a server. This error might occur due to various issues such as network connectivity problems, incorrect parameters, or limitations imposed by the system or service.

Developer Interpretation

When encountering this error, developers should consider several potential causes and take appropriate steps to resolve the issue. The following are common scenarios where this error might be observed:

  • Invalid Parameters: Ensure that all input parameters passed to the RPC function are valid and correctly formatted.
  • Network Issues: Verify that there is proper network connectivity between the client and server, and that firewalls or other security measures are not blocking the necessary communication.
  • Service Availability: Confirm that the remote service is running and accessible. Check if the service has any known issues or limitations.

Related Errors

  • RPC_S_SERVER_UNAVAILABLE (1728, 0x6C0): The server is not available to handle the request.
  • RPC_S_CALL_FAILED (1726, 0x6BE): The remote procedure call failed.
  • RPC_S_INVALID_BINDING (1734, 0x6D6): The binding handle passed to an RPC function was invalid or has been closed.

FAQ

Q: What does the error code RPC_S_CALL_FAILED mean?

A: It indicates that a remote procedure call failed. This is a generic error and can be caused by various issues such as network problems, incorrect parameters, or service unavailability.

Q: How can I troubleshoot this issue?

A: Review the context in which the RPC call was made, validate input parameters, ensure proper network connectivity, and confirm that the remote service is running correctly.

Summary

The error code RPC_S_CALL_FAILED (1726, 0x6BE) signifies a failure in a remote procedure call. Developers should consider common causes such as invalid parameters or network issues when interpreting this error. Proper validation and troubleshooting steps can help resolve the issue.